JUC-31F bimetal thermal switch
HC
Availability: | |
---|---|
Quantity: | |
JUC-31F bimetal thermostat bimetal thermal switch temperature controller
JUC-31F bimetal thermostat bimetal thermal switch is widely used in electrical equipment, electronic products, instruments, meters, power supply, household appliances and circuit boards for temperature controll and overheat protection.
Normal open, or Normal closed type
Switching cycles: 250V AC 2A: 10000 cycles; 48V DC 1A:30000 cycles; 5V DC 0.02A:100000 cycles
Action temperature:-40℃--+145℃
Contact resistance:≤50mΩ
Insulation resistance:≥100MΩ
Certificates: UL,TUV,CQC,CB
Dimension(mm):
Table of action temperature and recovery temperature:(Lower than room temperature)
Action temperature(±5℃) | Maximum recovery temperature | Minimum higher than action temperature |
0℃ | 20℃ | 5℃ |
5℃ | 25℃ | 5℃ |
10℃ | 30℃ | 5℃ |
15℃ | 35℃ | 5℃ |
Table of action temperature and recovery temperature:(Normal temperature)
Action temperature(±5℃) | Minimum recovery temperature | Minimum lower than action temperature |
40℃ | 20℃ | 5℃ |
45℃ | 25℃ | 5℃ |
50℃ | 30℃ | 5℃ |
55℃ | 30℃ | 5℃ |
60℃ | 35℃ | 5℃ |
65℃ | 40℃ | 5℃ |
70℃ | 45℃ | 6℃ |
75℃ | 45℃ | 6℃ |
80℃ | 50℃ | 6℃ |
85℃ | 55℃ | 6℃ |
90℃ | 60℃ | 6℃ |
95℃ | 60℃ | 6℃ |
100℃ | 65℃ | 7℃ |
105℃ | 70℃ | 7℃ |
110℃ | 75℃ | 7℃ |
115℃ | 75℃ | 8℃ |
120℃ | 80℃ | 8℃ |
125℃ | 85℃ | 9℃ |
130℃ | 90℃ | 9℃ |
Other models for your reference:
Package:
Storage Condition:
During the transport and storage, the packages can not be exposed to snows or rains, and should avoid strong force outside. It shouId be stored in a dry and ventilative warehouse.
Customers' special requests accepted. Pls contact us for more.
JUC-31F bimetal thermostat bimetal thermal switch temperature controller
JUC-31F bimetal thermostat bimetal thermal switch is widely used in electrical equipment, electronic products, instruments, meters, power supply, household appliances and circuit boards for temperature controll and overheat protection.
Normal open, or Normal closed type
Switching cycles: 250V AC 2A: 10000 cycles; 48V DC 1A:30000 cycles; 5V DC 0.02A:100000 cycles
Action temperature:-40℃--+145℃
Contact resistance:≤50mΩ
Insulation resistance:≥100MΩ
Certificates: UL,TUV,CQC,CB
Dimension(mm):
Table of action temperature and recovery temperature:(Lower than room temperature)
Action temperature(±5℃) | Maximum recovery temperature | Minimum higher than action temperature |
0℃ | 20℃ | 5℃ |
5℃ | 25℃ | 5℃ |
10℃ | 30℃ | 5℃ |
15℃ | 35℃ | 5℃ |
Table of action temperature and recovery temperature:(Normal temperature)
Action temperature(±5℃) | Minimum recovery temperature | Minimum lower than action temperature |
40℃ | 20℃ | 5℃ |
45℃ | 25℃ | 5℃ |
50℃ | 30℃ | 5℃ |
55℃ | 30℃ | 5℃ |
60℃ | 35℃ | 5℃ |
65℃ | 40℃ | 5℃ |
70℃ | 45℃ | 6℃ |
75℃ | 45℃ | 6℃ |
80℃ | 50℃ | 6℃ |
85℃ | 55℃ | 6℃ |
90℃ | 60℃ | 6℃ |
95℃ | 60℃ | 6℃ |
100℃ | 65℃ | 7℃ |
105℃ | 70℃ | 7℃ |
110℃ | 75℃ | 7℃ |
115℃ | 75℃ | 8℃ |
120℃ | 80℃ | 8℃ |
125℃ | 85℃ | 9℃ |
130℃ | 90℃ | 9℃ |
Other models for your reference:
Package:
Storage Condition:
During the transport and storage, the packages can not be exposed to snows or rains, and should avoid strong force outside. It shouId be stored in a dry and ventilative warehouse.
Customers' special requests accepted. Pls contact us for more.