KSD-A07
HC
Availability: | |
---|---|
Quantity: | |
KSD1 1/2 disk bimetal thermostat, Thermostat, ksd301 thermostat, Bimetal thermostat, ksd301 thermostat 16a 250v,ksd301 thermostat 16a 125v,ksd301 thermostat 10a 250v,KSD thermostat, ksd302 thermostat,temperature thermostat, electric water heater thermostat,water heater thermostat,thermostat for electric oven,thermostat switch,coffee maker thermostat,electric oven thermostat, ksd302 thermostat 250v 10a, ksd303 thermostat, thermostat ksd,ksd 202 thermostat,electric heating thermostat,boiler thermostat, thermostat temperature controller, high temperature thermostat,thermostat for water heater,toaster oven thermostat
Application:
Steam iron, steamer, coffee maker, and other electrical appliance.
Feature:
KSD1 bimetal thermostat 10A 16A with bakelite base or ceramic base
Automatic reset
Normal Closed
Open temperature: 0oC to 250oC,
Insulative resistance:
a.Between terminal and out can≥100MΩ;
b.Between contact points when they are in open conditioan≥5MΩ.
Contact resistance≤50mΩ
Electrical strength
a.It should be afford of such a test: Applying AC1500V between terminal and out
can for 1min, there should be no damage, or creeping action;
b. Applying AC660V between two contacts for 1min, there should be no damage,
or creeping action
Approval: UL, VDE, TUV, CQC, RoHs compliant
Endurance Test:
Low temperature endurance test:
1.Place the product in a constant temperature cabinet with temperature of
-20±3°C for 1 hour after the temperature becomes stable.
2. Take it out, then carry out high temperature endurance test according to clause 3.8. after 2 hours being placed in normal temperature environment.
High temperature endurance test:
1.Place the product in a constant temperature oven with temperature setting 150±3°C for 1 hour after the temperature becomes stable.
2. Take it out, then carry out low & high temperature shocking test according to clause 3.9. after 2 hours being placed in normal temperature environment.
Temperature shocking test:
Put the product in a constant temperature cabinet with -20±3°C for 0.5h,
then take it out in normal temperature environment for 2~3min,and then
put it in a constant temperature oven with 150±3°C for 0.5hour, thereafter
again take it out in normal temperature environment for 2~3min. After above 5 cycles tests, the temperature shift should be within ±3%°C of original temperature.
Humidity endurance:
After being placed in a constant temperature cabinet with 40±3°C, relative humidity 90%~95% for 48 hours, the insulation resistance between terminal and out can should>10MΩ;
Dropping test:
From 200mm high, freely drop the product to cement ground and other hard flat material with its six different sides (face, reverse, left, right, front, back), one time dropping for each side. The temperature shifts should be within ±3%°C of its original action temperature.;
Time endurance test:
The temperature shifts should be within±3%°C of its original action temperature after 1000,000 cycles performance under rated voltage and rated current condition.
Other models for your reference:
KSD1 1/2 disk bimetal thermostat, Thermostat, ksd301 thermostat, Bimetal thermostat, ksd301 thermostat 16a 250v,ksd301 thermostat 16a 125v,ksd301 thermostat 10a 250v,KSD thermostat, ksd302 thermostat,temperature thermostat, electric water heater thermostat,water heater thermostat,thermostat for electric oven,thermostat switch,coffee maker thermostat,electric oven thermostat, ksd302 thermostat 250v 10a, ksd303 thermostat, thermostat ksd,ksd 202 thermostat,electric heating thermostat,boiler thermostat, thermostat temperature controller, high temperature thermostat,thermostat for water heater,toaster oven thermostat
Application:
Steam iron, steamer, coffee maker, and other electrical appliance.
Feature:
KSD1 bimetal thermostat 10A 16A with bakelite base or ceramic base
Automatic reset
Normal Closed
Open temperature: 0oC to 250oC,
Insulative resistance:
a.Between terminal and out can≥100MΩ;
b.Between contact points when they are in open conditioan≥5MΩ.
Contact resistance≤50mΩ
Electrical strength
a.It should be afford of such a test: Applying AC1500V between terminal and out
can for 1min, there should be no damage, or creeping action;
b. Applying AC660V between two contacts for 1min, there should be no damage,
or creeping action
Approval: UL, VDE, TUV, CQC, RoHs compliant
Endurance Test:
Low temperature endurance test:
1.Place the product in a constant temperature cabinet with temperature of
-20±3°C for 1 hour after the temperature becomes stable.
2. Take it out, then carry out high temperature endurance test according to clause 3.8. after 2 hours being placed in normal temperature environment.
High temperature endurance test:
1.Place the product in a constant temperature oven with temperature setting 150±3°C for 1 hour after the temperature becomes stable.
2. Take it out, then carry out low & high temperature shocking test according to clause 3.9. after 2 hours being placed in normal temperature environment.
Temperature shocking test:
Put the product in a constant temperature cabinet with -20±3°C for 0.5h,
then take it out in normal temperature environment for 2~3min,and then
put it in a constant temperature oven with 150±3°C for 0.5hour, thereafter
again take it out in normal temperature environment for 2~3min. After above 5 cycles tests, the temperature shift should be within ±3%°C of original temperature.
Humidity endurance:
After being placed in a constant temperature cabinet with 40±3°C, relative humidity 90%~95% for 48 hours, the insulation resistance between terminal and out can should>10MΩ;
Dropping test:
From 200mm high, freely drop the product to cement ground and other hard flat material with its six different sides (face, reverse, left, right, front, back), one time dropping for each side. The temperature shifts should be within ±3%°C of its original action temperature.;
Time endurance test:
The temperature shifts should be within±3%°C of its original action temperature after 1000,000 cycles performance under rated voltage and rated current condition.
Other models for your reference: